Share
Electromagnetic Flowmeter
Classification
Keywords: Electromagnetic Flowmeter
- Product Description
-
LD Series Electromagnetic Flow Meter
This is a velocity-type flow meter. Based on electromagnetic induction principles, it enables accurate measurement of conductive fluids. It has no moving parts and the measurement results are independent of changes in the fluid’s temperature, pressure, viscosity, density, liquid-solid composition ratio and electrical conductivity.
Key Benefits:
No moving parts & low maintenance;
Wide measurement range;
Low power consumption;
Easy installation;
Long service life.
Working principle:
The flowmeter is equipped with detection electrodes and a magnetic field perpendicular to the direction of fluid flow. When a conductive fluid passes through, an induced electromotive force is generated at both ends of the conductor, which is mutually perpendicular to the direction of the magnetic field and the direction of motion. The magnitude of the electromotive force is proportional to the fluid's movement speed and the magnetic field strength. By detecting the electromotive force, the flow velocity of the fluid can be obtained. The flow velocity multiplied by the known cross-sectional area of the pipeline gives the fluid flow rate.

Basic Parameters
Model Series
LD
Housing Material
Carbon Steel, Stainless Steel
Liner Material
PTFE, PFA, PU, CR
Electrode Material
316L, Hastelloy C, Ti, Ta Platinum Alloy
Electrode Type
Standard Type, Scraper Type
Structure Type
Pipeline/Insertion (both includes Integral and Split Type)
Nominal Pressure
0.6~6.3Mpa
Nominal Diameter
10~3000mm
Display
Digital
Signal Output
Pulse/4-20mA/RS485/HART
Power Supply
3.6V/24VDC/220VAC (single supply)
IP Rating
IP65,IP68(submersible type, insertion, split)
Explosion-proof Rating
Exd IIC T6 Gb (optional)
Medium
Conductive Fluids
Accuracy
±0.5%;±1%
Electrical Conductivity
≥5μs/cm
Flow Velocity
0.3~15m/s
Flow Range
>0.03 m³/h
Medium Temperature
-20~60℃ (Integral Type)
-20~180℃(Split Type, differs with different liner material)
Ambient Condition
-25~60℃, Relative Humidity<95%,
avoid strong magnetic fields