Share
Vortex Flowmeter
Classification
Keywords: Vortex Flowmeter
- Product Description
-
LUGB Series Vortex Flow Meter
Using Karman vortex technology, this flow meter accurately measures steam, gases and low-viscosity liquids like water and gasoline.
Key Benefits:
No moving parts, minimal wear;
Easy installation & maintenance;
Multi-parameter measurement with optional configuration of temperature/pressure transducer (temperature/pressure);
Long service life.
Working principle:
A non-streamlined vortex generator is installed inside the flowmeter. When fluid passes through, two rows of regular vortices are alternately generated on both sides of the vortex generator, which is known as the Karman vortex street. The frequency of the vortices is proportional to the flow velocity. The volumetric flow rate of the fluid is obtained by detecting the vortex frequency through a built-in sensor.

Basic Parameters
Model Series
LUGB
Housing Material
SS304
Installation
Flange (DN25~450), Flange Clamp (DN25~200), Insertion
Nominal Pressure
1.6Mpa(DN250~300), 4.0Mpa(DN25~200)
Nominal Diameter
25~1000mm
(Pipeline type for DN25~450mm, Insertion Type for DN300mm and above)
Display
Digital
Signal Output
4-20mA two-wire system/Pulse three-wire system
Power Supply
12/24VDC for transducer & transmitter;
3.6VDC for onsite display only
IP Rating
IP65, IP68(Submersible Type)
Explosion-proof Rating
Exd IIC T6 Gb (optional)
Medium
Steam, Gases, Low-viscosity Liquids
Accuracy
±1%/±1.5% (Pipeline Type); ±2.5% (Insertion Type)
Flow Range
1.2~1700m³/h (Liquid), 8.8~170k m³/h (Gas)
Medium Temperature
-20~250℃ (up to 350℃ with high-temperature probe)
Ambient Condition
-20~55℃, Relative Humidity5~90%,
Atmospheric Pressure 86~106kPa
Remarks
Optional temperature & pressure compensation configuration for unstable T/P conditions.





Vortex Flowmeter